Notice-B: Definition of terms on Certificate of Calibration form_20200709

Dear KILEWS Partners,

Please find KILEWS KL-TCG Certificate of Calibration Form as attached and below listing as definition of terms on Certificate of Calibration form for your reference:

Type of Tool: SKT-CG Tool Model
Serial No: SKT-CG Tool S/N
Ambient Temp: Test surroundings temperature
Calibration Value: Slope value after calibration, each of tools has different defined value.
Test Torque: 80% of the maximum torque of SKT-CG model
(CG30: 2.4N.m, CG50: 4N.m, CG70:5.6N.m)
Internal Transducer: KL-TCG
Reference Transducer: Rotary Sensor – n-gineric(TTR500-xi)
Mean Torque: The results of 25 fasten times average value
Maximum Torque: Maximum torque value results in 25 times fasten.
Minimum Torque: Minimum torque value results in 25 times fasten.
Range: The result of the maximum value of the test torque minus the minimum value.
Standard Deviation: The result calculated using the standard deviation formula.
3S Scatter % of Mean Torque (3S): KILEWS SKT-CG tool standard is within 7.5% at 3 sigma as qualified.
Number of Test: Test for 25 times fasten.
Test Joint Type: Soft Joint/Angle: >=720 Degree. (KILEWS standard test joint as 900 Degree)

Wish this information can help your sales promotion for Kilews products.
If you have any suggestion for the contents, please do not hesitate to contact us.
Thank you very much for your kind attention.

Best Regards,

Loover-Kilews Industrial Co., Ltd.

P.S. Your confirmation of the message by return is necessary for us, thanks for your cooperation.